Your Professional Liquid Level Actuator Supplier

XINXIANG KAIRUI REFRIGERATION EQUIPMENT CO., LTD,is a professional manufacturing company integrating scientific research, design,production sales and service that serve the global. Our factory mainly produce all kinds of refrigeration filter and can be used for Carrier YORK, TRANE McQuay Bitzer Refcomp brand refrigeration units such as the supporting filter spot sales (part). We also sell chiller spare parts for these brands.

Professional Team

Our team of proficient experts is dedicated to building long-term partnerships with clients by delivering impeccable and reliable services.

Custom Service

We provide tailored solutions for the customization of various filter types to meet specific customer requirements.

Reasonable Price

We are committed to offering superior service and high-quality products at competitive and cost-effective prices.

 

Advanced Equipment

We have adopted world-leading technology and equipment from Europe and the United States, and have implemented robust quality control procedures and advanced production lines.

 

 
  • York 025-38180-000 Level Actuator
    The York Level actuator 025-38180-000 is a key component in the York refrigeration system. It relies on advanced electronic control technology to operate, its workflow is very sophisticated. If the
  • York Level Actuator
    The York Level actuator 025 38177 000 is a key component in the York refrigeration system. It relies on advanced electronic control technology to operate, its workflow is very sophisticated. If the
  • Trane Level Actuator
    Trane Level actuators SEN02128 play a key role in the field of level control. It uses specific sensor technology to accurately detect liquid level changes, and its working principle is diversified
 
Specification
 

Measurement range

0~1m,0~3m,...0~10m,0~50m,Max 200m

Working voltage

24VDC,12VDC(9~32V)

Output signal

4~20mA,1~5A,0~10mA

Combined accuracy

0.25%F.S

Delay, Repeatability

≤0.2%F.S

Zero drift

≤0.2%F.S/4H

Long term stability

≤0.2%F.S/year

Compensation temperature

0~50℃

Medium temperature

-40℃~60℃

Overload capacity

300%

 

Advantages of Liquid Level Actuator
 
York Level Actuator
 

Power Saver

Living in an age where we need to be more conscious of the energy that we use, a liquid level actuator is ideal at saving power. Normally, regulating water levels can consume electricity and wastewater.

 

Money Saver

A liquid level actuator helps save money by limiting the waste of water and electricity. These devices accurately regulate how much energy is used to protect against any unnecessary water/electricity usage.

3
5
 

Automatic

Another notable advantage with these devices is that they regulate on their own. Eliminating manual operations with a timer switch, the frustrations of manual monitoring water tanks are minimized.

 

Water Maximization

A liquid level actuator can maximize the water usage provided during midday while automatically lessening the water usage at night. This results in an appropriate level of water at all times being maintained, while providing you with the maximum use of your water at the appropriate times.

2

 

Applications of Liquid Level Actuator

Industrial Automation

In the realm of industrial automation, liquid level actuators are indispensable. They monitor and control the levels of liquids in tanks, reservoirs, and pipelines, ensuring uninterrupted production processes.

01

Automotive Industry

Liquid level transmitters find extensive use in the automotive industry, particularly in vehicles with advanced systems that require precise fluid level monitoring.

02

Environmental Monitoring

In environmental applications, liquid level transmitters are instrumental in monitoring water levels in rivers, lakes, reservoirs, and groundwater systems.

03

Medical Equipment

Liquid level transmitters play a crucial role in medical equipment such as dialysis machines, infusion pumps, and laboratory instruments.

04

Agriculture And Irrigation

In agriculture and irrigation, liquid level actuators are used to monitor and control water levels in irrigation systems, reservoirs, and storage tanks.

05

 

Installation Steps of Liquid Level Actuator

 

Preliminary Preparation and Inspection

Installation of a liquid level actuator is a work that can only be done after proper preparation and inspection. Therefore, make full preparations before installing the liquid level actuator. First of all, before installing the liquid level actuator, ensure that you have all the required tools and equipment.

Bracket Installation and Fixing

To get started, it is essential to understand that the liquid level actuator bracket is to be properly installed. Its exact position is to be determined with regard to the installation standards. Generally, the choice and the quality of installation of the bracket affect the actuator’s life cycle and efficiency of operation.

27

Hydraulic Line Connections

For the normal operation of the liquid level actuator, the connection of the hydraulic system is the foundation. The liquid level actuator requirements for hydraulic connection are as follows. According to the hydraulic circuit diagram of the liquid level actuator, connect the hydraulic pipelines respectively.

Electrical System Connection

Perform electrical connections according to electrical diagrams, all connections should be connected correctly. The power supply voltage should be 24V DC and during operation should not fluctuate more than ± 5%. Maintaining this parameter is very important for the normal operation of the actuator.

 

Ordering Process
 

 

Packaging and Shipping
 

Packaging

Carton with pearl bag and cushion inside,pallet and wooden crate available for mass order.

Shipping

UPS, DHL, FeDex, Sea and air freight, etc

 

 

Our Factory

 

productcate-1-1

productcate-1-1
productcate-1-1
productcate-1-1
 

FAQ

 

Q: What is the role of an actuator in a system?

A: Actuators convert energy into work by responding to a control signal. This results in motion.

Q: What could cause actuators to fail prematurely?

A: Typically, actuators fail due to application errors like excessive loading, poor mounting fixity, incorrect wiring, and exceeding duty cycle. Such issues can be avoided through a thorough system review and regular maintenance.

Q: Can actuators be repaired?

A: Actuator failures often occur due to improper use, such as excessive loading, improper mounting, incorrect wiring, or exceeding the recommended duty cycle.

Q: How to test if an actuator is working?

A: Connect a multimeter in series with one end of the actuator leads. Observe the amp readings while retracting and extending the rod. The readings will indicate the necessary power for the current draw.

Q: What is the common problem with actuators?

A: These can include an inadequate power supply, defective wiring or connections, a damaged motor, or the failure of internal components. To address this issue, verifying the power supply is essential. For instance, if utilizing a 12V linear actuator, one must ensure sufficient voltage.

Q: What does an actuator actually do?

A: Defined simply, an actuator is a device that converts energy, which may be electrical, hydraulic, or pneumatic, to mechanical output in such a way that it can be controlled. The quantity and the nature of input depend on the kind of energy to be converted and the function of the actuator.

As one of the leading liquid level actuator manufacturers and suppliers in China, we warmly welcome you to buy high quality liquid level actuator for sale here from our factory. Good service and competitive price are available.

York Level Actuator, York Liquid Level Actuator 025 38177 000, Refrigeration Spare Parts York Liquid Level Actuator
Send Inquiry